In this high impedance system example, the DP-4035i can drive up to 80 pcs of i8T loudspeakers in a 100 V system (20 per channel tapped at 25 w). This configuration can also drive LESS than 80 pcs of i8T. Any number between 1 and 80 !
Required Amplifier settings –
Set DP-4035i mode switch to “High Z 100 V”
HPF is set at 40 Hz by the amplifier automatically to avoid low frequency transformer saturation.
Limiters are set automatically for 70 V or 100 V power output.
DSP limiters should also be set to the total power and impedance of the speakers connected.